Tip
Need help? Please let us know in the SUEWS Community.
Please report issues with the manual on GitHub Issues (or use Report Issue for This Page for page-specific feedback).
Please cite SUEWS with proper information from our Zenodo page.
4.3.47. STEBBS#
STEBBS (Surface Temperature Energy Balance for Building Surfaces) model parameters.
Controls the building energy balance calculations including internal heating/cooling, building materials properties, and thermal behaviour.
Parameters:
- convection_coefficient_wall_internal#
Internal convection coefficient of walls [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.69- Default Description:
Default value calculated from the CIBSE GUIDE A, Table 3.47, Page 176
- Range Description:
Value must be greater than zero.
- convection_coefficient_roof_internal#
Internal convection coefficient of roof [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
10.0
- convection_coefficient_internal_mass#
Convection coefficient of internal mass [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.69
- convection_coefficient_ground_floor_internal#
Internal convection coefficient of ground floor [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
5.88
- convection_coefficient_window_internal#
Internal convection coefficient of windows [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.69
- convection_coefficient_wall_external#
Initial external convection coefficient of walls and roof [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
25.0
- convection_coefficient_roof_external#
Initial external convection coefficient of roof [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
25.0
- convection_coefficient_window_external#
Initial external convection coefficient of windows [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
25.0
- depth_ground#
Depth of external ground (deep soil) [m]
- Unit:
m
- Example:
3.0
- thermal_conductivity_ground#
External ground thermal conductivity
- Unit:
W m-1 K-1
- Example:
0.193
- threshold_metabolism#
threshold of metabolic rate to determine occupancy active or inactive [W]
- Unit:
W
- Example:
74.3
- ratio_latent_sensible#
Latent-to-sensible ratio of metabolic energy release of occupants [-]
- Unit:
dimensionless
- Example:
0.0
- daylight_control#
Integer flag to enable daylight-based lighting control (0 = off, 1 = on)
- Unit:
dimensionless
- Example:
0
- threshold_lighting_illuminance#
Indoor illuminance threshold above which electric lighting is switched off [lx]
- Unit:
lx
- Example:
300.0
- efficiency_heating_system_air#
Efficiency of space heating system [-]
- Unit:
dimensionless
- Example:
0.9
- max_power_cooling_system_air#
Maximum power demand of cooling system [W]
- Unit:
W
- Example:
0.0
- efficiency_cooling_system_air#
Coefficient of performance of cooling system [-]
- Unit:
dimensionless
- Example:
3.4
- rate_ventilation#
Ventilation rate (air changes per hour, ACH) [h-1]
- Unit:
h-1
- Example:
0.0
- temperature_air_outdoor_initial#
Initial outdoor temperature [degC]
- Unit:
degC
- Example:
0.0
- temperature_air_indoor_initial#
Initial indoor temperature [degC]
- Unit:
degC
- Example:
0.0
- temperature_air_annual_mean#
Annual mean air temperature [degC]
- Unit:
degC
- Example:
10.0
- temperature_air_month_mean_diffmax#
Maximum difference in monthly outdoor air temperature [degC]
- Unit:
degC
- Example:
10.0
- thickness_hot_water_tank_wall#
Hot water tank wall thickness [m]
- Unit:
m
- Example:
0.01
- temperature_mains_water#
Temperature of water coming into the water tank [degC]
- Unit:
degC
- Example:
0.0
- surface_area_hot_water_tank#
Surface area of hot water tank cylinder [m2]
- Unit:
m2
- Example:
2.0
- setpoint_temperature_heating_water#
Water tank setpoint temperature [degC]
- Unit:
degC
- Example:
60.0
- emissivity_hot_water_tank_wall#
Effective external wall emissivity of the hot water tank [-]
- Unit:
dimensionless
- Example:
0.0
- thickness_hot_water_vessel_wall#
Hot water vessel wall thickness [m]
- Unit:
m
- Example:
0.005
- volume_hot_water#
Volume of water held in use in building [m3]
- Unit:
m3
- Example:
0.05- Default Description:
Missing default explanation.
- Range Description:
Missing range explanation.
- surface_area_hot_water#
Surface area of hot water in vessels in building [m2]
- Unit:
m2
- Example:
0.5
- rate_flow_hot_water#
Hot water flow rate from tank to vessel [m3 s-1]
- Unit:
m3 s-1
- Example:
0.0
- profile_flow_hot_water#
Profile of hot water flow rate from tank to vessel [m3 s-1]
- Unit:
m3 s-1
The
profile_flow_hot_waterparameter group is defined by the Ten Minute Profile structure.
- specific_heat_capacity_hot_water#
Specific heat capacity of hot water [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
4186.0
- specific_heat_capacity_hot_water_tank_wall#
Specific heat capacity of hot water tank wall [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
500.0
- specific_heat_capacity_hot_water_vessel_wall#
Specific heat capacity of vessels containing hot water in use in buildings [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
500.0
- density_hot_water#
Density of hot water in use [kg m-3]
- Unit:
kg m-3
- Example:
1000.0
- density_hot_water_tank_wall#
Density of hot water tank wall [kg m-3]
- Unit:
kg m-3
- Example:
2500.0
- density_hot_water_vessel_wall#
Density of vessels containing hot water in use [kg m-3]
- Unit:
kg m-3
- Example:
2500.0
- conductivity_hot_water_tank_wall#
Effective wall conductivity of the hot water tank [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
0.5
- convection_coefficient_hot_water_tank_wall_internal#
Effective internal wall convection coefficient of the hot water tank [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.7
- convection_coefficient_hot_water_tank_wall_external#
Effective external wall convection coefficient of the hot water tank [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.7
- conductivity_hot_water_vessel_wall#
Effective wall conductivity of the hot water tank [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
0.5
- convection_coefficient_hot_water_tank_vessel_internal#
Effective internal wall convection coefficient of the vessels holding hot water in use in building [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.7
- convection_coefficient_hot_water_tank_vessel_external#
Effective external wall convection coefficient of the vessels holding hot water in use in building [W m-2 K-1]
- Unit:
W m-2 K-1
- Example:
7.7
- emissivity_hot_water_vessel_wall#
Effective external wall emissivity of hot water being used within building [-]
- Unit:
dimensionless
- Example:
0.9
- efficiency_heating_system_water#
Efficiency of hot water system [-]
- Unit:
dimensionless
- Example:
0.9
- profile_appliance#
10-minute profile of appliance usage factor in building [-]
- Unit:
dimensionless
The
profile_applianceparameter group is defined by the Ten Minute Profile structure.
- power_density_lighting#
Lighting power per building floor area [W m-2]
- Unit:
W m-2
- Example:
2
- ref#