Tip
Need help? Please let us know in the SUEWS Community.
Please report issues with the manual on GitHub Issues (or use Report Issue for This Page for page-specific feedback).
Please cite SUEWS with proper information from our Zenodo page.
4.3.3. Archetype Properties#
Urban morphology and archetype properties.
Parameters:
- archetype_name#
Building archetype name [-]
- Example:
'SampleBuilding'
- archetype_building_count#
Number of buildings of this archetype [-]
- Unit:
dimensionless
- Example:
1
- occupants#
Number of occupants present in building [-]
- Unit:
dimensionless
- Example:
1
- archetype_height#
Building height. This should be consistent with wall_external_area and footprint_area. [m]
- Unit:
m
- Example:
10.0
- area_footprint#
Building footprint area. This should be consistent with building_height and wall_external_area. [m2]
- Unit:
m2
- Example:
64.0
- area_wall_external#
External wall area (including window area). This should be consistent with building_height and footprint_area. [m2]
- Unit:
m2
- Example:
80.0
- ratio_internal_mass_volume#
Ratio of internal mass volume to total building volume [-]
- Unit:
dimensionless
- Example:
0.01
- area_internal_mass#
Surface area of internal mass used for indoor heat exchange [m2]
- Unit:
m2
- Example:
100
- ratio_window_to_wall#
window to wall ratio [-]
- Unit:
dimensionless
- Example:
0.2
- thickness_wall#
Thickness of external wall [m]
- Unit:
m
- Example:
0.2
- conductivity_wall#
Effective thermal conductivity of walls [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
0.6
- density_wall#
Effective density of the walls [kg m-3]
- Unit:
kg m-3
- Example:
1600.0
- specific_heat_capacity_wall#
Effective specific heat capacity of walls [J kg-1 K-1]
- Example:
850.0
- thickness_wall_outer#
Thickness of layers external to insulation in external wall [m]
- Unit:
m
- Example:
20.0
- conductivity_wall_outer#
Effective thermal conductivity of layers external to insulation in walls [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
60.0
- density_wall_outer#
Effective density of layers external to insulation in the walls [kg m-3]
- Unit:
kg m-3
- Example:
1600.0
- specific_heat_capacity_wall_outer#
Effective specific heat capacity of layers external to insulation in walls [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
850.0
- fraction_heat_capacity_wall_external#
Weighting factor (0-1) representing the fraction of wall heat capacity assigned to the external node, with the remainder assigned to the internal node [-]
- Unit:
dimensionless
- Example:
0.5
- emissivity_wall_external#
Emissivity of the external surface of walls [-]
- Unit:
dimensionless
- Example:
0.9
- emissivity_wall_internal#
Emissivity of the internal surface of walls [-]
- Unit:
dimensionless
- Example:
0.9
- transmissivity_wall_external#
Transmissivity of walls [-]
- Unit:
dimensionless
- Example:
0.0
- absorptivity_wall_external#
Absorptivity of walls [-]
- Unit:
dimensionless
- Example:
0.8
- reflectivity_wall_external#
Reflectivity of the external surface of walls [-]
- Unit:
dimensionless
- Example:
0.2
- thickness_roof#
Thickness of roof [m]
- Unit:
m
- Example:
20.0
- conductivity_roof#
Effective thermal conductivity of roof [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
60.0
- density_roof#
Effective density of the roof [kg m-3]
- Unit:
kg m-3
- Example:
1600.0
- specific_heat_capacity_roof#
Effective specific heat capacity of roof [J kg-1 K-1]
- Example:
850.0
- thickness_roof_outer#
Thickness of layers external to insulation in roof [m]
- Unit:
m
- Example:
20.0
- conductivity_roof_outer#
Effective thermal conductivity of layers external to insulation in roof [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
60.0
- density_roof_outer#
Effective density of layers external to insulation in the roof [kg m-3]
- Unit:
kg m-3
- Example:
1600.0
- specific_heat_capacity_roof_outer#
Effective specific heat capacity of layers external to insulation in roof [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
850.0
- fraction_heat_capacity_roof_external#
Weighting factor (0-1) representing the fraction of roof heat capacity assigned to the external node, with the remainder assigned to the internal node [-]
- Unit:
dimensionless
- Example:
0.5
- emissivity_roof_external#
Emissivity of the external surface of roof [-]
- Unit:
dimensionless
- Example:
0.9
- emissivity_roof_internal#
Emissivity of the internal surface of roof [-]
- Unit:
dimensionless
- Example:
0.9
- transmissivity_roof_external#
Transmissivity of roof [-]
- Unit:
dimensionless
- Example:
0.0
- absorptivity_roof_external#
Absorptivity of roof [-]
- Unit:
dimensionless
- Example:
0.8
- reflectivity_roof_external#
Reflectivity of the external surface of roof [-]
- Unit:
dimensionless
- Example:
0.2
- thickness_ground_floor#
Thickness of ground floor [m]
- Unit:
m
- Example:
0.2
- conductivity_ground_floor#
Effective thermal conductivity of ground floor [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
0.15
- density_ground_floor#
Effective density of the ground floor [kg m-3]
- Unit:
kg m-3
- Example:
500.0
- specific_heat_capacity_ground_floor#
Effective specific heat capacity of the ground floor [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
1500.0
- thickness_window#
Window thickness [m]
- Unit:
m
- Example:
0.015
- conductivity_window#
Effective thermal conductivity of windows [W m-1 K-1]
- Unit:
W m-1 K-1
- Example:
1.0
- density_window#
Effective density of the windows [kg m-3]
- Unit:
kg m-3
- Example:
2500.0
- specific_heat_capacity_window#
Effective specific heat capacity of windows [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
840.0
- emissivity_window_external#
Emissivity of the external surface of windows [-]
- Unit:
dimensionless
- Example:
0.9
- emissivity_window_internal#
Emissivity of the internal surface of windows [-]
- Unit:
dimensionless
- Example:
0.9
- transmissivity_window_external#
Transmissivity of windows [-]
- Unit:
dimensionless
- Example:
0.9
- absorptivity_window_external#
Absorptivity of windows [-]
- Unit:
dimensionless
- Example:
0.01
- reflectivity_window_external#
Reflectivity of the external surface of windows [-]
- Unit:
dimensionless
- Example:
0.09
- density_internal_mass#
Effective density of the internal mass [kg m-3]
- Unit:
kg m-3
- Example:
1000.0
- specific_heat_capacity_internal_mass#
Effective specific heat capacity of internal mass [J kg-1 K-1]
- Unit:
J kg-1 K-1
- Example:
1000.0
- emissivity_internal_mass#
Emissivity of internal mass [-]
- Unit:
dimensionless
- Example:
0.0
- max_power_heating_system_air#
Maximum power demand of heating system [W]
- Unit:
W
- Example:
0.0
- volume_hot_water_tank#
Volume of water in hot water tank [m3]
- Unit:
m3
- Example:
0.15
- max_power_heating_system_water#
Maximum power demand of water heating system [W]
- Unit:
W
- Example:
3000.0
- setpoint_temperature_heating_air#
Heating setpoint temperature [degC]
- Unit:
degC
- Example:
0.0
- setpoint_temperature_cooling_air#
Cooling setpoint temperature [degC]
- Unit:
degC
- Example:
26.0
- profile_setpoint_temperature_heating_air#
10-minute profile of heating setpoints temperature when Setpointmethod equals to 2 [degC]
- Unit:
degC
The
profile_setpoint_temperature_heating_airparameter group is defined by the Heating Setpoint Profile structure.
- profile_setpoint_temperature_cooling_air#
10-minute profile of cooling setpoints temperature when Setpointmethod equals to 2 [degC]
- Unit:
degC
The
profile_setpoint_temperature_cooling_airparameter group is defined by the Cooling Setpoint Profile structure.
- profile_metabolism#
Profile of occupants metabolism in building [-]
- Unit:
W
The
profile_metabolismparameter group is defined by the Ten Minute Profile structure.
- ref#
The
refparameter group is defined by the Reference Info structure.